Convention: All wall elevations are interior views (seen from inside the room looking at the wall). Ceiling views are reflected ceiling plans (RCP, looking up). All heights are from Finished Floor Level (AFF). Acoustic ceiling height = 2.75 m in all rooms.
Comprehensive wall elevation drawings for all 4 rooms. Acoustic treatments (panels, bass traps, QRD diffusers), electrical infrastructure (power outlets, data jacks, stageboxes), doors, windows, and lighting — all from SSOT via DXF.
Drawing Legend
Wall Types
| ID | Name | STC | Used By |
|---|---|---|---|
| 1 | North concrete wall | STC 65 | VO North, Studio North |
| 2 | NW diagonal concrete | STC 65 | VO West, Control West (diagonal concrete) |
| 3 | East server wall | STC 62 | Studio East, Editing East |
| 4 | South rebuilt | STC 50 | Control South, Editing South |
| 5 | Buffer spine | STC 55 | VO East, Control East, Studio West, Editing West (buffer spine) |
| 6 | VO/Control partition | STC 53 | VO South / Control North (partition) |
| 7 | Video Studio/Editing partition | STC 48 | Studio South / Editing North (partition) — upgraded v3.2: 2×12.5mm + Green Glue |
SSOT v3.2 · March 2026 · Source: DXF → ezdxf → verified